Strumentazione Analitica

HT3™ Static and Dynamic Headspace Analyzer

HT3-LogoStatic Headspace analysis is a time-tested and robust technique for the analysis of volatile compounds in almost any matrix. The popularity of the technique is due to Headspace analysis providing a clean, reliable result. HT3

Teledyne Tekmar draws on our experience as a leader in low-level VOC analysis with the introduction of a next generation Headspace instrument, the HT3™ Static and Dynamic Headspace System.

Dramatic improvements in sensitivity are achieved with the new Dynamic Headspace option, while maintaining the ruggedness and reliability of a traditional Static Headspace instrument.

  admin   Feb 03, 2016     Commenti disabilitati su HT3™ Static and Dynamic Headspace Analyzer   Read More

Atomx Automated VOC Sample Prep System

The latest advancement in VOC instrumentation by Tekmar is the Atomx Automated Sample Prep System.  The Atomx combines an Autosampler and Purge and Trap into a single instrument for the analysis of VOCs in soils and waters. This is the first of its kind and only system that employs a unique methanol extraction automation feature for high level soils in accordance with USEPA Method 5035.
Atomx Automated VOC Sample Prep System
Extractasol clean-up step (patent pending) in the Atomx reduces carryover or cross contamination normally associated with high-level water or soil analysis. Three new independent injection systems for internal standards, surrogates, and matrix spikes provide the ability to select variable volumes without generating waste.

The Atomx features Tekmar’s proven carousel drive capable of holding 80-vials for optimal throughput therefore reducing downtime. While priced competitively, this system offers unique features that cannot be found on other sample prep systems on the market today.

Features:

  • Single platform system autosampler with built-in purge and trap for all water and soil matrices including drinking water and wastewater
  • Capable of sampling low level and high level soil samples
  • Only system to automate labor intensive Methanol Extractions
  • Utilizes proven 80-position carousel design for optimal throughput
  • Utilizes a digital Mass Flow Controller (MFC) for independent mode flow control (patent pending)
  • Chiller options available for EPA requirements
  • Ability to vary sample volume in 1mL aliquots from 1-25mL
  • Reduce carryover with Extractasol – dedicated methanol port for rinsing needle, sample lines, and glassware
  • Water reservoir included with standard instrument package
  • Three – 15mL UV-protected standard spiking vessels prevent possible compound break-down. Capable of varying volume delivery in 1, 2, 5, 10, and 20µL aliquots and zero waste
  • Shortest soil pathway on the market
  • Automated system leak check diagnostics
  • CFR compliance tools available
  • Small footprint saves bench space

 

  admin   Feb 03, 2016     Commenti disabilitati su Atomx Automated VOC Sample Prep System   Read More

AIM-8800

aim8800_large

This intelligent infrared microscope provides convenient control of stage movement, aperture setting and focusing, all from the PC screen. Supporting analysis using transmission, reflection as well as ATR methods, the AIM-8800 widens the range of application fields. With emphasis on sensitivity for basic performance of this infrared microscope, ease of operation was also a high design priority. The AIM-8800 Infrared Microscope advances one step further into the new generation.

Complete Control with AIM View

 

Auto Aperture – Maximizes IR illumination on the sample spot.

The aperture is motor-driven, and its size and angle are freely set using mouse operation alone. Simply set the aperture over the sample, and the sampling area is automatically positioned for maximum infrared intensity. The aperture size and angle are always maintained.

Auto X-Y Stage – Simplifies exact sample positioning.

Up to 10 sample positions and 2 background positions can be placed into memory, and the stage can be moved in increments as small as 1µm for finely detailed mapping.

Auto Focus – True focus is only one mouse-click away!

Arduous focusing is unnecessary. Just one click of the mouse automatically brings the image into focus.

Auto Centering – Sample viewing couldn’t be easier!Complete Control with AIM View

 

Double-clicking on any point in the visible observation screen will bring that spot to the center of the viewing area.
(Note : AIM View is the register trade mark of the software used to control the AIM-8800 Shimadzu Infrared Microscope

High Sensitivity, Maintenance-Free MCT Detector

 

High sensitivity – of course! A signal-to-noise ratio of 2600 to 1 is guaranteed in transmission measurement. The high-sensitivity glass dewar type MCT detector eliminates the need to re-evacuate every 1 to 2 years, as required with metallic dewar type MCT detectors.

AIM-8800 Specifications

Optics :

15 x Cassegrain objective
15 x Cassegrain condenser mirrors
w / inlet for purging

MCT detector :

w / liquid nitrogen monitoring systemWavelength range :
Type 1 – 5000 – 720cm-1
Type 2 – 5000 – 650cm-1

Electrically activated apertur

XY Θ directional drive. Setting of XY direction increments is 1µm over sample surface, and 1° increments in Θ direction (numerical entry possible).
Minimum setting value : 3µm

Motor-driven X-Y sample stage

Positioning range : X axis : 70mm; Y axis : 30mm Resolution : 1µm pitchSample thickness :
Reflection mode – ≤ 40mm
transmission mode – ≤ 10mm

Operation control via main unit keyboard

Measuring mode selection / XY stage operation (speed variable in 4 steps) / manual focusing / illumination control

Control via PC

Measuring mode selection / XY stage operation / auto centering / manual focusing / auto focusing / illumination control / aperture setting / aperture preview / measurement position and aperture setting recording (10 sample positions, 2 background positions)

Ambient conditions :

Ambient temperature : 15°C ~ 30°C
Ambient humidity : 70% or less

External dimensions, weight :

W410mm x D540mm x H520mm x 36kg

Power requirements :

AC100 / 120 / 220 / 230 / 240V 125VA

Options

  • Ge prism ATR objective
  • Diamond ATR objective (Spectra Tech)
  • ZnSe ATR objective (Spectra Tech)
  • Grazing angle objective (Spectra Tech)
  • Visual objective lens (10X)

Note :
When connected to a PC type FTIR-8000 Series, the PC for operating the FTIR main unit is also used for operating the AIM-8800. When connected to a non-PC type FTIR-8000 Series, the PC must be purchased separately.

  admin   Feb 02, 2016     Commenti disabilitati su AIM-8800   Read More

IRAffinity-1S

Fourier Transform Infrared Spectrophotometer

The Trinias series is equipped with innovative from-the-ground-up designs applying the SCORE, SMART and SMILE philosophy that sets Shimadzu apart:

The IRAffinity-1S is a compact Fourier transform infrared spectrophotometer that is housed within an elegant form. The interferometer is continuously optimized by a dynamic alignment mechanism, and a built-in auto dryer helps ensure ease of maintenance. The IRAffinity-1S offers the high S/N ratio (30,000:1, 1-minute accumulation, neighborhood of 2,100 cm-1, peak-to-peak), a maximum resolution of 0.5 cm-1, and compact dimensions. Furthermore, the high-performance LabSolutions IR software, which emphasizes operability, and analysis support programs (Contaminant analysis program and Pharma Report program) make it easier to perform data processing and analysis.

Highest S/N Ratio in Its Class: 30,000:1

Through the incorporation of a high-energy ceramic light source, a temperature-controlled, high-sensitivity DLATGS detector, a high-throughput optical element, and the optimization of the electrical system and optical system, the IRAffinity-1S achieves the highest S/N ratio in its class.

Ease of Maintenance Ensured by Built-in Auto Dryer

Beam splitters in the interferometers of FTIR instruments are susceptible to humidity. In order to maintain the long-term stability of the interferometer, the beam splitter must be protected. In the IRAffinity-1S, the interferometer is airtight and incorporates a unique internal auto dryer.

Fast, Easy-to-Use LabSolutions IR Series Software

Contaminant analysis program

By combining Shimadzu’s own algorithms (patent pending) with that of library spectra for common contaminants, this program identifies contaminants with a high degree of accuracy. Reports are automatically created after analysis, thereby reducing post-processing time to a few seconds. With automated reporting, this easy-to-use program allows operators with little FTIR knowledge to perform analysis easily.

Identification test program

This program makes pass/fail judgments about samples in accordance with the tests specified in the Pharmacopoeia. In addition to identification tests for pharmaceutical products, this program can be used for incoming inspections and pre-shipment inspections.

Smart Design

The IRAffinity-1S achieves a reduction of approximately 20% in installation area and width (compared with other Shimadzu products).

 

A Wide Range of Accessories

Various accessories, to best meet your application requirements, are available.

 

 

 

  admin   Feb 02, 2016     Commenti disabilitati su IRAffinity-1S   Read More

UV-1280

Designed by the leaders in UV-Visible Spectroscopy for molecular absorption quantitative analysis, the UV-1280 Multipurpose UV-Visible Spectrophotometer offers wavelength scanning from 190-1100nm. This lower-cost, high-quality instrument is ideal for applications ranging from routine environmental and food quality testing to life science analyses.

Features

1. Easy to Operate

The easy-to-see LCD and buttons enable userfriendly, intuitive measurement, instrument validation, and printing operations.

 

Instrument validation functions have been enhanced.

  • The checks for JIS items can be performed automatically or semiautomatically.
  • Linking with a 6-series multi-cell (optional) is possible, making sample replacement unnecessary. Inspections can be performed efficiently.

 

2. A Variety of High-Level Measurement Modes

Equipped with a range of programs, the UV-1280 can be used for everything from photometric, spectral, and kinetics measurements to DNA/protein and high-level multi-component quantitation.

Photometric ModeMeasures the absorbance or transmittance at a single wavelength or multiple (up to eight) wavelengths. The instrument is also capable of simple quantitation using the K-factor method. For a multiple-wavelength measurement, calculations can be performed on the data obtained for up to four wavelengths, including the calculation of the difference between, or ratio of, the measurements obtained for two wavelengths.
Spectrum ModeA sample spectrum is recorded using wavelength scanning. Repeat scans let you follow sample changes over time. Zoom in on the finished spectrum for a better view; subsequently, use the peak/valley pick function to select maxima and minima and perform a wide variety of data processing functions.
Quantitation ModeGenerates a calibration curve from the measurement of standards, and then calculates the concentrations of unknowns. Allows various combinations of wavelength number (1 to 3 wavelengths and derivatives) and calibration curves (K-factor and first-to-third order).
Kinetics ModeMeasures absorbance changes as a function of time, and obtains the enzymatic activity values. The kinetics measurement method automatically calculates the amount of change per minute, and then calculates an activity value from a specified coefficient. The rate measurement method, which determines whether the absorbance is changing linearly, can also be selected. In addition, add the CPS-100 thermoelectrically temperature-controlled cell positioner for measurement of multiple samples in succession.
Time Scan ModeMeasures the change in absorbance, transmittance or energy as a function of time. Add the CPS-100 thermoelectrically temperature-controlled cell positioner for simultaneous measurement of multiple samples under constant-temperature conditions.
Multi-Component Quantitation ModeQuantitates up to eight components mixed in a single sample. The calibration equation is determined using pure or mixed components with known values.
Biomethod ModeDetermine DNA and protein concentrations with the following quantitation methods using the bioscience/life science program included as standard.

DNA/Protein Quantitation

  • Quantitates DNA or protein using the absorbance at 260/230 nm or 260/280 nm.

Protein Quantitation

  • Lowry method
  • BCA method (method using bicinchoninic acid)
  • Biuret method
  • CBB method (method using Coomassie Brilliant Blue G-250)
  • UV absorption method (direct measurement at 280 nm)

3. Data Storage on USB USB Flash Drives

Using USB flash drives makes it easy to transp
ort analysis data and to store large amounts of data in a PC.

  • USB flash drives can be connected directly to the UV- 1280.
  • Data for spectra and time-course curves can be displayed and saved with commercial spreadsheet software.
  admin   Feb 02, 2016     Commenti disabilitati su UV-1280   Read More

UV-2600, UV-2700

Experience the precision desired, in any situation

UV2600, UV2700
The compact UV-2600/2700 is a universal, research-
grade spectrophotometer that can be used in a wide
range of fields, and easily expanded to suit the
measurement objective.
By using the optional integrating sphere, the
measurement wavelength range of the UV-2600 can
be extended to the near-infrared region of 1400 nm.
The UV-2700 is capable of 8-Abs measurements, and
optimal for measuring low transmittance samples.
Validation software is provided as standard for both
instruments, so equipment performance can be easily
checked in daily inspections and when data accuracy
becomes a concern.

Single Monochromator UV-2600

Enables Near-Infrared Measurements

By installing the ISR-2600Plus two-detector integrating
sphere, the 300 nm to 1100 nm wavelength range of
conventional models can be extended to 1400 nm.
As a result, the UV-2600 can accommodate measurements
of solar cell anti-reflective films and polycrystalline silicon wafers.

Transmission Measurements of Polycrystalline Silicon Using the ISR-2600Plus

This is a transmission measurement of polycrystalline
silicon. Since the system is capable of measurements
to 1400 nm, the transmission characteristics of the band
gap region (near 1000 nm) are clearly evident.

Relative Diffuse Reflection Measurements of an Anti-Reflective Film Using the ISR-2600Plus

This is a reflection measurement of an anti-reflective
film. With relative reflection measurements, the system
can measure from the ultraviolet region up to the
near-infrared region, so the suppressed reflectance
in the visible region is clearly evident.

Double Monochromator UV-2700

Capable of 8-Abs Measurements

With the ability to make accurate transmittance
measurements to 0.000001 %( 1 part in 100 million),
the UV-2700 can be applied to evaluating the transmission
characteristics of polarization films. In addition, even
high-concentration samples can be measured without

diluting, contributing to a savings in power use.The figure on the right shows the relationship between

the absorbance and the concentration of an aqueous
potassium permanganate solution.
Good linearity is evident to 8 Abs.

Spectral Comparison of Aqueous Potassium Permanganate Solutions

 

This spectrum is measured from an aqueous KMnO4 (potassium permanganate) solution. Unlike conventional models, this system is capable of high-level absorbance measurements.
Shimadzu’s proprietary Lo-Ray-Ligh diffraction grating enables
the high precision of the UV-2700. In the diffraction grating
production process, new proprietary manufacturing methods
have been developed for Shimadzu’s holographic technology.
By optimizing the etching process, we have successfully
manufactured extremely low stray light diffraction gratings while
maintaining high efficiency. With this newly designed optical
system equipped with a double Lo-Ray-Ligh monochromator,
the UV-2700 achieves unparalleled ultra-low stray light levels.

Even More Compact and User-Friendly

Reduced Size and Power Consumption

The installation space required for this system
has been reduced by about 28 % in comparison
to conventional models*, thanks to a brand new
compact design. In addition, the cooling fan is
built into the side of the unit, so that it can be
pushed back all the way to the wall. By placing in
contact with the wall, limited bench space can be
more effectively utilized. Furthermore, power
consumption has been reduced to 170 VA, a 10 %
energy savings that makes the system more

environmentally friendly.* Conventional model: UV-2450/2550

Validation Software Provided as Standard to Support GLP/GMP

Validation software assists with equipment performance
checks and the logging of such checks. By including it as
standard with the UV-2600/2700, easier instrument checks
are achieved. Equipment performance can be easily checked
in daily inspections and when data accuracy becomes a concern.
 
  • Inspection results can not only be printed, but also saved to a file, with results called up later for confirmation.
  • Inspection conditions for each periodic and routine inspection can be saved as a file, and then called up for use.

 

 

 

 

Equipment performance can be checked according to the performance indication standards specified in JIS K0115 “General rules for molecular absorptiometric analysis,” as well as to Japanese Pharmacopoeia general test methods or various EP and USP inspection methods. (Inspection tools and reagents must be prepared separately.)

Multifunctional, User-Friendly UVProbe Software

UVProbe is an all-in-one software package equipped with a multitude of functions to enable easy analysis from measurement to reporting. Additionally, functions for supporting GLP/GMP, such as security and audit trail functions, have been enhance
  admin   Feb 02, 2016     Commenti disabilitati su UV-2600, UV-2700   Read More

UV-3600 Plus

Incorporating the latest technology to achieve high sensitivity, high resolution, and an ultra-low stray light level, leading the way to new solutions

 

 

 

Features

High Sensitivity

Shimadzu developed the world’s first UV-VIS-NIR spectrophotometer with three detectors, consisting of a PMT (photomultiplier tube) for the ultraviolet and visible regions and InGaAs and cooled PbS detectors for the near-infrared region. With conventional instruments that use only PMT and PbS detectors, there is a drop in sensitivity in the crossover region between those detectors. Using an InGaAs detector to cover this crossover region, however, ensures high sensitivity across the entire measured wavelength range, and gives a noise level of 0.00003 Abs at 1500 nm. In addition to the main UV-3600 Plus unit, the Multi-purpose large-sample compartment and the Integrating sphere attachment also feature three detector, enabling the high-sensitivity measurement of solid samples.

 

High Resolution, Ultra-Low Stray-Light, and Wide Wavelength Range

A high-performance double monochromator makes it possible to attain an ultra-low stray-light level (0.00005 % max. at 340 nm) with a high resolution (maximum resolution: 0.1 nm). The wide wavelength range of 185 to 3,300 nm enables measurement across the ultraviolet, visible, and near-infrared regions. This instrument can perform spectrophotometry for a variety of applications.

 

Wide Range of Optional Accessories

The three-detector Multi-purpose large-sample compartment or Integrating sphere options enable high-sensitivity measurement of solid samples. Use the ASR Series of absolute specular reflectance accessories to perform high-accuracy absolute reflectance measurements. In addition, temperature-controlled cell holders and micro cell holders are available to handle a wide range of measurement applications.

 

A Wealth of Applications

Transmittance Measurement of Lenses

Imaging devices, such as mobile phones, digital cameras, and security cameras, are all equipped with lenses. The transmittance of a lens is one factor that determines lens performance. However, because the lens itself focuses light, it is an especially difficult type of sample to measure accurately.
Because of the focal capability of lenses, the total light passing through the spectrophotometer during the measurement of the baseline can be different than that after passing through the lens during measurement due to refraction. In such cases, the use of an integrating sphere can be used to collect all the light passing through the lens and provide for more accurate measurements. In addition, using the transmission-type integrating sphere included with the BIS-603 can reduce measurement errors.
Furthermore, using the V stage, provided as standard on the MPC-603 multi-purpose large-sample compartment, allows measuring the transmittance of lenses of various lengths and sizes. The MPC-603 and BIS-603 are an ideal combination for measuring lenses.

 

 

Options Used for Measurements

MPC-603
Multi-Purpose Large-Sample Compartment

This multi-purpose sample compartment allows measurement of various shaped samples to obtain both reflection and transmission spectra. An integrating sphere is built-in to ensure accurate measurement of solid samples.

BIS-603
Sample Base Plate Integrating Sphere Set

This base plate is used to install an absolute specular reflectance attachment in the MPC-603 multi-purpose chamber.

 

Band Gap Calculation

Research into solar-cell and photocatalytic materials often involves the measurement of the band gap, which is a basic physical property of the materials. Shown below are the diffuse reflectance spectra of three semiconductor materials used in the production of solar cells using the ISR-603 integrating sphere. The absorption edge, the wavelength where the reflectance decreases, differs depending upon the sample type. This difference indicates a difference in the band gap* of the samples. The band gaps of the samples were calculated using the Tauc method, and were determined to be 1.63ev for GuGaSe2 (red line) 1.27 eV for Culn0.5Ga0.5Se2 (blue line) and 0.99 eV for CuInSe2 (black line).

* The band gap refers to the energy difference between the top of the valence band filled with electrons and the bottom of the conduction band devoid of electrons. The wavelength range of the UV-3600 Plus is extremely effective for band gap calculations.
* The samples are courtesy of the Wada Laboratory, Faculty Science and Technology, Ryukoku University.

 

SampleBand Gap Value
CuGaSe21.63 eV (757nm)
Culn0.5Ga0.5Se21.27 eV (977nm)
CuInSe20.99 eV (1253nm)

 

 

Options Used for Measurements

Excel Macro for Band Gap Calculation

ISR-603 Integrating Sphere Attachment

This attachment is used for the measurement of diffuse and spealar reflectance. Transmission of liquid and solid samples can also be measured.

 

Option

Optional Software

  • DTL-UVPC Solar Transmittance Measurement Software
  • Color Measurement Software
  • Film Thickness Measurement Software

 

Accessories

UV accessory selection guide for liquids, for solids

 

The Advantages of Double-Grating Monochromators

The UV-3600 Plus uses gratings for both the pre-monochromator and main monochromator. Our holographic diffraction gratings are designed to achieve high efficiencies and exceptionally low stray-light levels. Furthermore, to improve light energy efficiency, blazed gratings are used for wavelength regions that by nature have low light source energy or lower detector sensitivity. A G-G system that uses gratings for both the pre-monochromator and main monochromator ensures low stray light, with a constant optimal resolution of 0.1 nm in the ultraviolet and visible regions and 0.4 nm in the near-infrared region.

  admin   Feb 02, 2016     Commenti disabilitati su UV-3600 Plus   Read More

UV-1800

UV-VIS spectrophotometer achieves a resolution of 1 nm, the highest in its class, in a compact design.

Designed in accordance with the governing JapaneseSpectroscopy Products UV-1800
and European Pharmacopoeia, the new UV-1800 UV-VIS
spectrophotometer achieves a resolution of 1 nm, the highest
in its class, in a compact design.
Offering an array of user-friendly features, the UV-1800 can be
used either as a stand-alone instrument or as a PC-controlled
instrument.

High resolution – 1 nm

Featuring the highest resolution in its class*, the UV-1800Toluene/hexane solution
easily satisfies the standards of wavelength resolution
demanded by the European Pharmacopoeia.
Additionally, using a spectroscope with a Czerny-Turner
mounting results in a compact, bright optical system. Stray
light, wavelength repeatability and baseline stability have also
been advanced to meet user requirements.
*As of March 2007, according to Shimadzu research.

Space-saving designOnly 450 mm wide, the UV-1800 is one of the most compact instruments in its class

Only 450 mm wide, the UV-1800 is one of the
most compact instruments in its class, allowing
installation in tight spaces. In comparison to the
UV-1700, the setting space has decreased by about
15%, and the width has narrowed by about 20%.

User friendly

USB memory can be connected directly to the UV-1800. Users can now analyze data on a PC using UVProbe software. In addition, data for spectra and time-course curves can be displayed and saved with commercial spreadsheet software. Printing is possible to printers that support PCL control codes.
e.g. HP Business Inkjet 1200
HP Photosmart D5160Using UVProbe software, provided as standard, makes it possible to control the UV-1800 with a PC. (A USB cable is required for connection to the PC.)
USB memory can be connected directly to the UV-1800
  admin   Feb 02, 2016     Commenti disabilitati su UV-1800   Read More

BioSpec-nano

Spectrophotometer for Life Sciences

 

The BioSpec-nano is a spectrophotometer suitable for carrying out concentration checks for DNA and RNA nucleic acid samples. Quantitation of DNA and RNA can be rapidly and simply carried out with very small samples ranging from 1µL, and analysis throughput is improved due to dedicated functions, such as automated sample mounting and wiping, and easy-to-use operation software

Automatic Mounting and Wiping Function

All operations from sample mounting to measurement and wiping are automatically performed. Tedious operations are unnecessary.

Sample dropping, Sample auto mount function, Auto wiping function

Quick Analysis

start button in software window, instrument start button

Just drop the sample onto the target and click the button. That’s all there is to analysis. The instrument will perform sample mounting, measurement, and wiping. No need to move the wiper arm manually, nor wipe the liquid-contact parts with a cloth. Spectra measurement is conducted and the analysis data is obtained quickly.

1 µL – 2 µL Nucleic Acid Quantitaion *

Analysis can be performed with 1 µL (pathlength: 0.2 mm) or 2 µL (pathlength: 0.7 mm) samples. The sample is dropped onto the target with a pipette. The optional 5 mm cell allows measurement of 5 mm path length. * If the surface tension of the sample is small, droplets might not be formed with a 1 to 2 µL sample.

Easy-to-use Software

Basic operations can be conveniently performed by clicking icons in the software or function keys on the instrument itself. Analysis results can be converted to PDF or CSV files.
Easy-to-use software
  admin   Feb 02, 2016     Commenti disabilitati su BioSpec-nano   Read More

SolidSpec-3700/3700DUV

Solution for optics, semiconductors and FPD applications –
Shimadzu UV-VIS-NIR Spectrophotometer

 qn50420000005tx1
Shimadzu SolidSpec-3700/3700DUV are the top-of-the-line spectrophotometer with high sensitivity,  deep UV measurement and a large sample compartment. The SolidSpec-3700/3700DUV respond to the following requirements in optical, semiconductor and FPD applications.
FPD:
High-sensitivity measurement in NIR and a large sample compartment for material evaluation
Semiconductors:
Deep UV measurement in accordance with shorter wavelength laser, and 12-inch wafer whole surface measurement
Optical communications:
High-sensitivity measurement of anti-reflection films in NIR
Optics:
High-sensitivity measurement from deep UV to NIR, and a large sample compartment

SolidSpec-3700/3700DUV Features

 

High Sensitivity
The SolidSpec-3700 and 3700DUV are the FIRST UV-VIS-NIR SPECTROPHOTOMETERS with THREE DETECTORS: a photomultiplier tube (PMT) detector for the ultraviolet and visible region; InGaAs and PbS detectors for the near-infrared region. The use of the InGaAs and PbS detectors makes the sensitivity in the near-infrared region significantly high.
Deep UV Measurement
The SolidSpec-3700DUV has the capability to measure the deep ultaviolet region
dwon to 165nm(note) (or to 175nm with an itegrating sphere) by purging both
the optical and the sample compartment with nitrogen gas.
Note) 165nm is the minimum wavelength for SolidSpec-3700DUV with its optical attachment, Direct Detection Unit DDU-DUV.
Large Sample Compartment
The large sample compartment (900W x 700D x 350H mm) allows large samples to be measured without destroying the sample. The vertical optical path makes it possible to measure large samples while keeping them horizontal. The whole sample area of 12 inches or 310 x 310 mm samples is measurable by mounting the automatic X-Y stage (option).
Optional Accessories
Direct Detection Unit DDU/DDU-DUV (for liquid/solid transmission measurements)
Automatic X-Y Stage (for automated measurement)
Large Specular Reflectance Attachment
Nitrogen Gas Flow Meter
Absolute Specular Reflectance Attachments (5°12°30°45°)
Sample Base Plate Integrating Sphere Set

Specifications

 

Hardware

 

Wavelength rangeSolidSpec-3700: 240-2600nm, 190-3300nm(when using Direct Deteciton Unit DDU)
SolidSpec-3700DUV: 175-2600nm, 165-3300nm(when using Direct Deteciton Unit DDU-DUV)
Spectral bandwidth
Spectral bandwidthUV/VIS: 0.1-8nm (8 steps)
NIR: 0.2-32nm (10 steps)
Resolution(*)0.1nm
Wavelength accuracy(*)UV/VIS: ±0.2nm, NIR: ±0.8nm
Wavelength repeatability(*)UV/VIS: ±0.08nm, NIR: ±0.32nm
Stray light(*)Less than 0.00008% (220nm), less than 0.00005% (340nm) Less than 0.0005% (1420nm), less than 0.005%(2365nm)
NoiseUnder 0.0002Abs (500nm, SBW 8nm), Under 0.00005Abs (1500nm, SBW 8nm) determined under conditons of RMS value at 0Abs and 1second responce. When using Direct Ditection Unit DDU/DDU-DUV, Under 0.00005Abs(500nm,SBW 2nm),
Under 0.00008Abs(900nm, SBW 2nm), Under 0.00003Abs(1500nm,SBW 2nm) determined under condition of RMS value at 0Abs and 1 second responce.
Photometric range-6 to 6Abs
Photometric systemDouble beam, direct ratio measuring system
Dimensions1000W x 800D x 1200H mm, 170kg

(* Determined with Direct Detection Unit DDU)

All-in-one Software

 

UVProbe software for the SolidSpec-3700/3700DUV includes functions for spectrum measurement, quantitation, kinetics and a report generator. Multiple security and audit-trail functions ensure the reliability of data.
  admin   Feb 02, 2016     Commenti disabilitati su SolidSpec-3700/3700DUV   Read More